Skip to main content

v0.3 profile repeat audit and measurement plan

This audit follows the published v0.2 post-hoc analysis. It changes no frozen v0.2 inputs or conclusions. The source profiles are RTX 4070 and GB10 at revision 0.21.0-posthoc in commit d26fa24. The proposed measurements are microbenchmarks and require review before collection. Future captures on both devices follow the draft long-launch protocol. Long-launch recapture plan

What the profiles establish​

A timed sample is one observation within a sweep. An independent repeat is a fresh process running the sweep. The profile stores rounded median and bootstrap interval values. It has no sample count, repeat count, or point-level raw receipt. Equal interval endpoints can occur with repeated identical or rounded readings and with derived and clipped metrics. They cannot identify single timed samples. No curve field can be verified as having exactly one timed sample from the published evidence. The inventory below marks curves backed by a single contributing sweep separately from fields where repeat provenance is unavailable.

Bytes-in-flight MLP inventory​

The paths below are relative to measured.memory. The flat interval column is a check on the profile representation, independent of whether the contributing sweep was repeated.

Curve fieldRTX 4070 points / flat intervalsGB10 points / flat intervalsPublished evidence
dram_bw_by_bytes_in_flight[].bw_gbps48 / 848 / 3mlp supplies 24 points for each issue mode in one sweep. The GB10 curve still matches the initial profile in 4be40fe. Its archived five-repeat medians differ at 47 points.
l2_bw_by_bytes_in_flight[].bw_gbps48 / 148 / 0Same sweep, with the warm L2 working set. The GB10 curve still matches 4be40fe; repeat medians differ at 41 points.
dram_bw_by_bytes_in_flight_strided[].bw_gbps40 / 840 / 3The 40 values on each GPU still match the curve introduced by the strided-mlp sweep in 51336b5. No independent repeat series is published for this field.

For RTX 4070 the two contiguous curves match those in a4fc6e3. The collector requests 11 timed samples per point for mlp and 7 for strided-mlp, each invoked once in a full calibration. No independent-repeat aggregate is documented for the shipped RTX 4070 MLP values. The two GB10 cp_async DRAM points at 256 and 384 KiB have nonzero interval widths in the shipped profile. Their shipped values are 197.212 and 221.780 GB/s, versus 236.006 and 243.289 GB/s in the historical five-repeat series. Its 96 MLP rows join on memory level, issue mode, bytes in flight, active CTAs and bytes per CTA. That archive does not contain full timed samples or per-run clock and thermal records.

Other curve fields without installed repeat provenance​

A curve from a different benchmark family is outside the proposed MLP refresh. The groups below enumerate those fields so the review can identify any follow-up. There are no per-point repeat counts in either profile. The GB10 repeat archive covers only delivered_bw_gbps in the two plain closed-loop sweeps, at 360 points each. Their shipped curves are unchanged from 4be40fe. No published repeat archive was identified for the other outputs below. Undocumented repeats remain unknown.

Relative to measuredCurve fields
memorydram_bw_by_active_sms, l2_bw_by_active_sms, dram_latency_by_bw, l2_latency_by_bw, l2_rescan_hit_rate_by_working_set
memorydram_closed_loop, l2_closed_loop, dram_closed_loop_mma, l2_merge_by_sharing
memorygmem_load_issue_per_sm, gmem_load_issue_controlled, spill_reload_latency_by_count, spill_reload_latency_scattered_diagnostic, spill_reload_latency_serial_halfws_diagnostic, l1_to_l2_spill_threshold_by_carveout including its nested miss-rate curve
computemma_tflops_per_sm_by_warps, mma_chain_latency, serial_stage_overhead_ns, sfu_issue_rate_per_sm_gips, sfu_rcp_issue_rate_per_sm_gips, shfl_issue_rate_per_sm_gips, shfl_idx_issue_rate_per_sm_gips, mma_softmax_chain (RTX 4070 only, 72 points)
pipelinestage_sync_overhead_ns, fixed_sync_ns, serial_stage_fill, sync_stage_loop, sync_stage_loop_ablation, sync_stage_loop_pre_reconcile_diagnostic
cta_dispatchprobes (five geometry points per GPU)

Original collection design​

  1. Use the same pinned microbenchmark sources on Bifrost RTX 4070 and Spark 1 GB10. Build for sm_89 and sm_121 respectively. Verify exact geometry keys and units against the shipped MLP matrices.
  2. Run five fresh processes per benchmark per GPU, with 15 timed samples per point. Use mlp --samples 15 --warmup 3 for contiguous DRAM and L2 and strided-mlp --samples 15 --warmup 3 for strided DRAM. Keep each benchmark's existing working sets, issue modes, read-only DRAM eviction and warm L2 preparation. Repeat the whole registered grid, including the outliers and their neighbors.
  3. Hold flock /tmp/virtualgpu-gpu.lock for each invocation. Check compute processes and display activity before and after. Defer the 4070 when gaming or other GPU work is active. On Spark 1 also check CPU and memory activity because the GPU shares host memory. For future sweeps on either device, warm at least 60 seconds and require adjacent 30-second temperature means within 0.5 C, SM clock medians within 1%, and both windows clear of thermal and power slowdown. Stop and save the trace if the gate times out at 20 minutes. Use verified locked clocks when available. Otherwise record frequencies, temperature, throttling and power policy. Preserve and report any protocol failure separately. Keep completed independent repeats in UTC order and retain all valid samples.
  4. Join by full geometry keys, require five complete repeat rows per key, and use the median of the five within-sweep medians. Publish all five medians and their minimum and maximum. Archive the pooled 75-sample median and interquartile range per point as descriptive statistics across individual timed observations. Use the existing bootstrap median interval over the five independent sweeps as a coarse interval. Apply the existing clock uncertainty calculation with measured drift and the GB10 record-only uncertainty floor. Preserve observed nonmonotonicity. Audit the read bandwidth scalars that can alias an MLP peak. If a scalar used an old point, recompute it from its independent bandwidth sweep and the refreshed MLP peak using the existing maximum rule, with its input sources recorded.
  5. Increment both profile revisions from the latest merged revisions (proposed 0.22.0-posthoc if available). Publish a calibration manifest digest referencing the previous profile, source and binary SHA, GPU identity, driver, toolkit, commands, run IDs, UTC, host checks, raw samples and telemetry SHA-256, and the reduction procedure. Validate schema and profile consumers and review the field-level diff before freezing. Keep this calibration separate from workload labels and evaluation commits.

GB10 calibration record​

Spark 1 completed five contiguous and five strided sweeps on 2026-11-26 UTC. The first sweep used a fixed 60-second warmup. Its 70 recorded temperature samples span 59.51 seconds and give adjacent 30-second means of 45.77 and 48.17 C, a 2.40 C increase. The historical capture had no thermal gate. The other nine sweeps used the three per-point warmups without an additional device soak. The timed runs recorded 48 to 52 C and a 2470 MHz SM clock. Memory clocks were unavailable through nvidia-smi. No thermal, hardware power-brake, or software power-cap event was sampled. The previously captured sweeps remain the source of this reduction. The profile retains the base calibration's global clock policy. This refresh's clock data is in the calibration manifest.

The GB10 0.22.0-posthoc MLP acquisition is unqualified under the adopted dispersion rules. The independent audit reported that 10 of 10 sweeps exceeded the 5% limit on points with IQR/median above 10% and that the five-process comparisons failed the reproducibility gate. In the contiguous comparison, 11 of 96 points (11.46%) had process medians whose range exceeded 10% of their median. The permitted share is 5%. The superseded max/min-above-1.3 check flagged 13.5% to 32.5% of points per sweep. The MLP curves and their two derived read ceilings are provisional pending a long-launch recapture. Revision 0.21.0-posthoc also used short launches and lacks the raw samples for this audit. The profile retains its installed values and binds this status through its calibration digest. GB10 quality amendment

The new GB10 revision is 0.22.0-posthoc. At 256 KiB and 384 KiB, the DRAM cp_async medians are 227.803 and 241.015 GB/s. The 256 KiB point had one low sweep at 190.858 GB/s, which is included in the manifest. The DRAM and L2 read bandwidth ceilings are 263.550 and 2276.489 GB/s. Both ceilings use the existing maximum rule and still come from the contiguous MLP curves.

The GB10 calibration manifest records the ten raw report SHA-256 digests, UTC times, telemetry summary, and all 136 point reductions. The original reports with raw samples and telemetry are archived on Spark 1 under ~/virtualgpu/v03-mlp-7bb3d7f/runs/ and on Bifrost under results/v03-mlp/gb10/. The capture script snapshot and source-bundle digest identify the run independently of subsequent reducer edits. The review bundle, results/v03-mlp/review/gb10-mlp-audited.tar.gz, contains the original reports, exact capture script, base profile, and reduction manifest. Its SHA-256 is 82916275c0069c9c3df30ae875639fae05ed755fd33cbca548feac37edccd8dd. The RTX 4070 calibration is pending a reviewed long-launch protocol and an idle device.

RTX 4070 same-session bandwidth refresh​

The long-launch protocol carries forward the same-session refresh of dram_bw_by_active_sms and l2_bw_by_active_sms alongside the MLP curves. It also replaces the temporary RTX 4070 dispersion rule with the adopted three checks. Long-launch recapture plan