Result: the GB10 DRAM read probe, four formal sessions
Registered analysis. The plan and its pilot bounds were frozen before these sessions, and its decision rule is applied here unchanged, by microbench/probe_analyze.py (which marks its own output post_hoc, as every analysis tool here does). Two things were not in the plan and are reported as such: the host CPU check (microbench/host_trace.py), which ran from session 2 on, and one session postponed for another capture. No GEMM or attention timing enters anything here.
Data
- Spark 1 (GB10), binary
b75ca0b(sha256in each session file), driver as recorded there;microbench/probe_blocks.py --blocks 20 --gap-seconds 30 --samples 15, workloadmlp-plateau(14 MLP plateau points,cp_asyncandld_global_v4, 512 KiB to 7.5 MiB in flight), probes P1, P2, P3a and P3b before and after the workload in each block, all under one short lock per block. - Sessions: session-1.json from 21:52 UTC on 2026-11-26, then 2 from 00:04, 3 from 02:24 and 4 from 04:27 on 2026-11-27. Session 4 was due at 04:46 and was postponed until the
0.23.0GB10 capture released the GPU; it started at 04:25, 2 h 8 min after session 3 started and 1 h 39 min after it ended. The thermal gate passed before every session (GPU at 52 to 54 C, SM clock median 2496 to 2515 MHz). - Host check (host-judge.json): every block's window, from its state before to its state after, judged by the
host_trace.pyrule (total CPU busy share at most 10% in every sample, no other process above 5% of one CPU for two consecutive samples). Sessions 2 and 4 pass in all 20 blocks. In session 3, block 10 fails: a compiler (cc1plus) ran beside it for two samples; the block is voided. Session 1 ran before the sampler started; its blocks' own/proc/statdeltas show a busy share of 4.8% to 5.4% (the capture itself), and 9.9% in its last block, 19. - No block was flagged as drift: in every block and for every candidate, the probes before and after differ by less than the frozen 3%.
Result
Probe medians per session (GB/s) fall in the same order for every candidate, by 3% to 4% over the six and a half hours, and the workload falls with them (cp_async at 1.5 MiB: 251.9, 244.0, 241.6, 240.5):
| Probe | Session 1 | 2 | 3 | 4 |
|---|---|---|---|---|
| P1 | 252.9 | 246.1 | 243.2 | 242.0 |
| P2 | 250.3 | 243.9 | 242.5 | 241.5 |
| P3a | 245.2 | 240.3 | 238.5 | 237.7 |
| P3b | 244.3 | 239.1 | 237.4 | 236.8 |
Coefficients of variation (CV) of the 14 workload points, absolute and over each block's own probe (analysis.json; session 3 without block 10; across sessions, the CV of the four session medians, with 95% intervals from resampling blocks within sessions):
| Probe | Across sessions, absolute | Across sessions, ratio | Within sessions, absolute | Within sessions, ratio | Points passing the rule |
|---|---|---|---|---|---|
| P1 | 1.10% to 1.83% | 0.15% to 0.63% | 0.38% to 0.91% | 0.49% to 1.03% | 13 of 14 |
| P2 | 1.10% to 1.83% | 0.04% to 0.38% | 0.38% to 0.91% | 0.47% to 0.99% | 14 of 14 |
| P3a | 1.10% to 1.83% | 0.03% to 0.56% | 0.38% to 0.91% | 0.50% to 0.97% | 14 of 14 |
| P3b | 1.10% to 1.83% | 0.02% to 0.54% | 0.38% to 0.91% | 0.48% to 0.99% | 14 of 14 |
The one point that misses with P1 is cp_async at 6 MiB: ratio CV 0.63% against 1.10% absolute, not at most half. The same counts follow with session 3's voided block kept (analysis-with-voided-block.json) and with session 1's block 19 also left out (analysis-without-s1-block-19.json), and the drift exclusion changes nothing since no block was flagged.
Decision, by the frozen rule: the ratio is adopted for this workload with P2, P3a and P3b at every point, and with P1 at 13 of 14.
What it does and does not show:
- The probe removes a drift that the session shares: absolute values move by about 4% between sessions hours apart, the ratio by well under 1%.
- Within a session the ratio is slightly noisier than the absolute value (0.47% to 1.03% against 0.38% to 0.91%), since it adds the probe's own noise; the gain is across sessions only.
- The cause of the drift is not known. Temperature and SM clock at the thermal gate were the same in all sessions; nothing recorded tracks it. Four sessions on one machine in one night, with the same monotone fall, are not a sample of all the states a profile capture can meet.
- The ratio is checked for MLP plateau reads beside the probe, not for other modes.
What the profile gets
Agreed with the profile owner (5). The schema and the collector are a separate change by the owner, after review of this contract; this document changes neither.
- The absolute fields stay. No ratio is stored; a reader computes it from the absolute value and its reference.
- Reference probe: P3a (
ld.global.v4, 4 loads in flight per thread). P2, P3a and P3b all pass at 14 of 14 points; P3a is chosen because it is separate from thecp.asyncimplementation and is not itself one of the MLP points it would normalize. P2 and P3b stay in reports as controls. It is a session reference, not a ceiling: a ratio above 1 is allowed. - Reference value, as reduced in this analysis:
value_gbps = (median(before samples) + median(after samples)) / 2, the probe's median in the same block before and after the values it serves. - Optional top-level
references, keyed by ID. Each entry holds the device;session_idandblock_id; the probe (geometry name, protocol and issue mode, active SMs, cache preparation);value_gbps; the before and after samples, each with its UTC; the source revision and binary digest; whether the block is valid or flagged (voided by a gate, or drift by the frozen 3% bound); and a digest of the raw capture. - Pairing. Only a rate and a reference captured in the same locked block may be paired. A single block observation may carry a
reference_id. An aggregatedMeasuredValueover rounds does not carry one ID, and its value is never divided by one block's reference or by an aggregated reference. - Recomputing a normalized value. The profile keeps each block observation as a pair (
reference_id,value_gbps); the ratio is formed block by block first, then reduced over independent sessions, as here (median over blocks within a session, then over sessions). Errors of values sharing one reference share that denominator's error. - Voided and drift blocks stay in the audit record under the frozen rules; qualified aggregates are formed as before. Existing
0.23.0data gets no references after the fact. - Scope. The evidence covers these 14 MLP plateau points on this GB10 only. Low bytes in flight,
closed-loopand active-SM curves need their own same-block reproduction before a reference is used for them.
Limits
- One GB10, four sessions in one night. Sessions start at least two hours apart; session 4 started 1 h 39 min after session 3 ended.
- Session 1 has no per-process host record.
- The intervals resample blocks within each session and keep the four sessions fixed, so they show block noise, not how much another set of sessions would differ. With four sessions a CV is coarse.